## WPF AppDomain Shutdown Handling May Now Call Dispatcher.Invoke in Cleanup of Weak Events
|
||
|
|
||
|
### Scope
|
||
|
Edge
|
||
|
|
||
|
### Version Introduced
|
||
|
4.7.2
|
||
|
|
||
|
### Source Analyzer Status
|
||
|
NotPlanned
|
||
|
|
||
|
### Change Description
|
||
|
In .NET Framework 4.7.1 and earlier versions, WPF potentially creates a <xref:System.Windows.Threading.Dispatcher?displayProperty=nameWithType> on the .NET finalizer thread during AppDomain shutdown. This was fixed in
|
||
|
.NET Framework 4.7.2 and later versions by making the cleanup of weak events thread-aware. Due to this, WPF may call <xref:System.Windows.Threading.Dispatcher.Invoke%2A?displayProperty=nameWithType> to complete the cleanup process.
|
||
|
|
||
|
In certain applications, this change in finalizer timing can potentially cause exceptions during AppDomain or process shutdown. This is generally seen in applications that do not correctly
|
||
|
shut down dispatchers running on worker threads prior to process or AppDomain shutdown. Such applications should take care to properly manage the lifetime of dispatchers.
|
||
|
|
||
|
- [X] Quirked
|
||
|
- [ ] Build-time break
|
||
|
|
||
|
### Recommended Action
|
||
|
In .NET Framework 4.7.2 and later versions, developers can disable this fix in order to help alleviate (but not eliminate) timing issues that may occur due to the cleanup change.
|
||
|
|
||
|
To disable the change in cleanup, use the following AppContext flag.
|
||
|
|
||
|
```xml
|
||
|
<configuration>
|
||
|
<runtime>
|
||
|
<AppContextSwitchOverrides value="Switch.MS.Internal.DoNotInvokeInWeakEventTableShutdownListener=true"/>
|
||
|
</runtime>
|
||
|
</configuration>
|
||
|
```
|
||
|
|
||
|
### Affected APIs
|
||
|
Not detectable via API analysis
|
||
|
|
||
|
### Category
|
||
|
Windows Presentation Foundation (WPF)
|
||
|
|
||
|
<!--
|
||
|