## ETW event names cannot differ only by a "Start" or "Stop" suffix
|
|
|
|
### Scope
|
|
Edge
|
|
|
|
### Version Introduced
|
|
4.6
|
|
|
|
|
|
### Version Reverted
|
|
4.6.2
|
|
|
|
### Source Analyzer Status
|
|
NotPlanned
|
|
|
|
### Change Description
|
|
In the .NET Framework 4.6 and 4.6.1, the runtime throws an <xref:System.ArgumentException> when two Event Tracing for Windows (ETW) event names differ only by a "Start" or "Stop" suffix (as when one event is named `LogUser` and another is named `LogUserStart`). In this case, the runtime cannot construct the event source, which cannot emit any logging.
|
|
|
|
- [X] Quirked
|
|
- [ ] Build-time break
|
|
|
|
### Recommended Action
|
|
|
|
To prevent the exception, ensure that no two event names differ only by a "Start" or "Stop" suffix.
|
|
|
|
This requirement is removed starting with the .NET Framework 4.6.2; the runtime can disambiguate event names that differ only by the "Start" and "Stop" suffix.
|
|
|
|
### Affected APIs
|
|
* Not detectable via API analysis
|
|
|
|
### Category
|
|
Core
|
|
|
|