1.4 KiB
1.4 KiB
Crash in Selector when removing an item from a custom INCC collection
Scope
Minor
Version Introduced
4.7
Version Reverted
4.7.1
Source Analyzer Status
NotPlanned
Change Description
An T:System.InvalidOperationException
can occur in the following scenario:
- The ItemsSource for a
T:System.Windows.Controls.Primitives.Selector
is a collection with a custom implementation ofT:System.Collections.Specialized.INotifyCollectionChanged
. - The selected item is removed from the collection.
- The
T:System.Collections.Specialized.NotifyCollectionChangedEventArgs
hasP:System.Collections.Specialized.NotifyCollectionChangedEventArgs.OldStartingIndex
= -1 (indicating an unknown position).
The exception's callstack begins at System.Windows.Threading.Dispatcher.VerifyAccess() at System.Windows.DependencyObject.GetValue(DependencyProperty dp) at System.Windows.Controls.Primitives.Selector.GetIsSelected(DependencyObject element)
This exception can occur in .Net 4.5 if the application has more than one Dispatcher thread. In .Net 4.7 the exception can also occur in applications with a single Dispatcher thread. The issue is fixed in .Net 4.7.1.
- Quirked
- Build-time break
Recommended Action
Upgrade to .Net 4.7.1.
Affected APIs
- Not detectable via API analysis
Category